A symbol or string specifying the Lisp name the module will be registered under.
A keyword determining when the connection to the dynamic library is made. One of
:automatic
,
:manual
or
:immediate
. The default value is
:automatic
.
A keyword specifying the lifetime of the connection. One of
:indefinite
or
:session
. The default value is
:indefinite.
Overrides the name for identifying the actual dynamic library to connect to.
Controls use of
dlopen
on Unix-based systems. One of
t
,
nil
,
:local-now
,
:global-now
,
:global-lazy
,
:local-lazy
, or a fixnum. The default value is
nil
on Darwin, and
t
on other platforms.
The function
register-module
explicitly informs LispWorks of the presence of a DLL or shared object file, referred to here as a dynamic library. Functions such as make-pointer and define-foreign-function have a
module
keyword which can be used to specify which module the function refers to.
The main use of modules is to overcome ambiguities that can arise when two different dynamic libraries have functions with the same name.
If an application is delivered after calling
register-module
, then the application attempts to reload the module on startup but does not report any errors. Therefore it is strongly recommended that you call
register-module
during initialization of your application, rather than at compile time or build time. Loading the module at run time allows you to:
You should compute and supply the appropriate full path if possible.
name
is used for explicit look up from the
:module
keyword of functions such as define-foreign-function. If
name
is a symbol, then
real-name
should also be passed to provide a filename. If
real-name
is not specified then
name
must be a string and specifies the actual name of the dynamic library to connect to.
The naming convention for the module name can contain the full pathname for the dynamic library. For example, a pathname such as
#p"C:/MYPRODUCT/LIBS/MYLIBRARY.DLL"
"C:\\MYPRODUCT\\LIBS\\MYLIBRARY.DLL"
On Windows, if the module is declared without an extension, "
.DLL
" is automatically appended to the name. To declare a name without an extension it must end with the period character ("
.
"). On other platforms, you should provide the extension, since there is more than one library format. Typical would be
.so
on Linux or FreeBSD and
.dylib
on Macintosh.
If a full pathname is not specified for the module, then it is searched for.
On Windows the following directories (in the given order) are searched:
GetSystemDirectory
). For XP/Vista/7 the 16-bit system directory (
SYSTEM
) is also searched.
GetWindowsDirectory
)
PATH
variable.
The simplest approach is usually to place the DLL in the same directory as the LispWorks executable or application. However if you really need different directories then be sure to call
register-module
at run time with the appropriate pathname.
On Linux, the search is conducted in this order:
LD_LIBRARY
path environment variable.
/etc/ld.so.cache
.
/usr/lib
, followed by
/lib
.
If
connection-style
is
:automatic
then the system automatically connects to a dynamic library when it needs to resolve currently undefined foreign symbols.
If
connection-style
is
:manual
then the system only connects to the dynamic library if the symbol to resolve is explicitly marked as coming from this module via the
:module
keyword of functions such as define-foreign-function.
Note: on LispWorks for UNIX only (not LispWorks for Linux, FreeBSD, or x86/x64 Solaris) this value
:manual
for
connection-style
is not supported.
If
connection-style
is
:immediate
then the connection to the dynamic library is made immediately. This checks that the library can actually be loaded before its symbols are actually needed: an error is signalled if loading fails.
If
lifetime
is
:session
then the module is disconnected when Lisp starts up. The only supported value of
lifetime
in LispWorks for UNIX is
:indefinite
.
You should load only libraries of the correct architecture into LispWorks. You will need to obtain a 32-bit dynamic library for use with 32-bit LispWorks and similarly you need a 64-bit dynamic library for use with 64-bit LispWorks. (If you build the dynamic library, pass
-m32
or
-m64
as appropriate to
cc
.) You can conditionalize the argument to
register-module
as in the example below.
Note: On Linux, you may see a spurious "No such file or directory" error message when loading a dynamic library of the wrong architecture. The spurious message might be localized.
Note: In LispWorks for UNIX the loader function
link-load:read-foreign-modules
is now deprecated in favor of
register-module
.
Note: static libraries are not supported except on UNIX. For example, on Linux evaluating this form:
(fli:register-module "libc.a"
:real-name "/usr/lib/libc.a"
:connection-style :immediate)
Could not register handle for external module "libc"
/usr/lib/libc.a : invalid ELF header
The problem is that
libc.a
is a static library. Instead, do:
(fli:register-module "libc.so"
:real-name "libc.so.6"
:connection-style :immediate)
Note that
:real-name
is given a relative path in this case, because
libc
is a standard library on Linux and it is best to let the operating system locate it.
dlopen-flags
has an effect only on Unix-based systems. It controls the value that is passed to
dlopen
as second argument when the module is connected, and on Darwin it also controls whether
dlopen
is used at all.
The keyword values of
dlopen-flags
correspond to combinations of
RTLD_*
constants (see
/usr/include/dlfcn.h
). The value
t
means the same as
:local-lazy
. The value
nil
means the same as
t
except on Darwin. On Darwin the value
nil
means do not use
dlopen
, and use the older interfaces instead.
A fixnum value means pass this value
dlopen-flags
to
dlopen
without checking. It is the responsibility of the caller to get it right in this case.
The default value of
dlopen-flags
is
nil
on Darwin, because it seems
dlopen
does not work properly on this platform.
register-module
during initialization of your application, rather than at compile time or build time.
In the following example on Windows, the
user32
DLL is registered, and then a foreign function called
set-cursor-pos
is defined to explicitly reference the
SetCursorPos
function in the
user32
DLL.
(fli:register-module :user-dll :real-name "user32")
(fli:define-foreign-function (set-cursor-pos
"SetCursorPos")
((x :long)
(y :long))
:module :user-dll)
This example on Linux loads the shared library even though its symbols are not yet needed. An error is signalled if loading fails:
(fli:register-module "libX11.so"
:connection-style :immediate)
This example loads a module from the same directory as the Lisp executable, by executing this code at runtime:
(fli:register-module
modulename
:file-name
(merge-pathnames "modulefilename.dylib"
(lisp-image-name)))
In this last example a program which runs in both 32-bit LispWorks and 64-bit LispWorks loads the correct library for each architecture:
(fli:register-module #+:lispworks-32bit "mylib32"
#+:lispworks-64bit "mylib64")
connected-module-pathname
define-foreign-function
make-pointer
module-unresolved-symbols
print-foreign-modules
LispWorks Foreign Language Interface User Guide and Reference Manual - 7 Dec 2011